Heat-resistant Cable

  • Berger Spezialkabel - Your partner for companies

In the field of specialized cables, we offer high-temperature lines, resisting up to 220°C / 250°C continuous temperature for flexible applications. On special request we produce cables with a maximum continuous deployment temperature of up to 1300°C.

Many other core numbers and cross-sections are possible, also in screened versions.

Our team is happy to give advice!

BERGOTHERM 150

Construction:

Conductor: tinned copper

Core insulation: special elastomer

Core identification: optional

Stranding: Cores stranded optimally

Jacket insulation: special elastomer, flame-retardant or halogen-free

Jacket color: gray, similar to RAL 7001

Nominal voltage: 300/500 V      0.6 / 1 kV

(further voltage ranges on request)

Temperature range: still: -50 ° C to + 130 ° C, moving: -40 ° C to + 125 ° C

max. 150 ° C without tensile stress: approx. 400 hours

  • flexible
  • good resistance to thermal shocks, ozone and oxygen
  • excellent aging in hot environments
  • very good notch resistance
  • UV resistance possible on customer request

Optional:

Braided screen (tinned copper)

Setup according to individual customer requirements

Material changes possible according to the area of ​​application

Changes and errors excepted.

BERGOTHERM 180

Construction:

Conductor: tinned copper

Core insulation: special silicone

Core identification: according to DIN VDE 0293-308 (optional from 300m)

(up to 5 cores colored, from 6 cores black with numbers)

Stranding: Cores stranded optimally

Jacket insulation: special silicone

Jacket color: black (RAL 9005)

Nominal voltage: 300/500 V (other voltage ranges from production possible)

Temperature range: unmoved: -60 ° C to + 180 ° C

moved: -25 ° C to + 180 ° C

  • halogen free
  • very good notch resistance
  • mechanic solidity

Optional:

Braided screen (tinned copper)

Setup according to individual customer requirements

Material changes possible according to the area of ​​application

Changes and errors excepted

BERGOTHERM 180 suitable for drag chains

Construction:

Conductor: tinned copper

Core insulation: special fluoroplastic

Core identification: optional

Stranding: Cores stranded optimally

Jacket insulation: special silicone

Jacket color: optional

Nominal voltage:     300/500 V 0.6 / 1 kV

(further voltage ranges on request)

Temperature range: moving / still: -25 ° C to + 180 ° C

  • good notch resistance
  • mechanic solidity

Optional:

Braid: tinned copper

Changes and errors excepted

BERGOTHERM 200

Construction:

Conductor: tinned copper

Core insulation: special silicone

Core identification: optional

Stranding: Cores stranded optimally

Jacket insulation: special silicone

Jacket color: black, or according to customer requirements

Nominal voltage:    300/500 V 0.6 / 1 kV

(further voltage ranges on request)

Temperature range: moving / still: -40 ° C to + 180 ° C (20000 hours), + 200 ° C for 3000h

  • highly flexible
  • good resistance to thermal shocks, moisture and hydrocarbon
  • excellent aging in hot and cold environments
  • good notch resistance
  • mechanic solidity

Optional:

Braided screen (tinned copper)

Thermo or compensating line (insulating materials)

Setup according to individual customer requirements

Material changes possible according to the area of ​​application

Changes and errors excepted.

BERGOTHERM 250

Construction:

Conductor: nickel-plated copper

Core insulation: special fluoroplastic

Core identification: optional

Stranding: Cores stranded optimally

Jacket insulation: special silicone

Jacket color: red, or according to customer requirements

Nominal voltage:     300/500 V 0.6 / 1 kV

(further voltage ranges on request)

Temperature range: unmoved: -40 ° C to +200 to + 220 ° C, briefly up to 250 ° C

moved: -25 ° C to +200 to + 220 ° C

  • flame retardant
  • 3.3 mm wall thickness, also changeable on request
  • good resistance to thermal shocks
  • excellent aging in hot and cold environments
  • highly flexible
  • very good notch resistance
  • strong mechanical load

Optional:

Braided screen (nickel-plated copper)

Thermo or compensating line (insulating materials)

Setup according to individual customer requirements

Material changes possible according to the area of ​​application

Changes and errors excepted.

BERGOTHERM 350

Construction:

Conductor: nickel-plated copper

Core insulation: special glass silk

Core identification: optional

Sheath insulation: special glass silk

Nominal voltage:           300/500 V    0.6 / 1 kV

(further voltage ranges on request)

Temperature range:        -50 ° C to + 350 ° C, briefly + 1575 ° C

  • good resistance to thermal shocks
  • excellent aging in hot and cold environments
  • only suitable for fixed installation in a dry environment

Optional:

Braided screen (nickel-plated copper)

Thermo or compensating line (insulating materials)

Setup according to individual customer requirements

Changes and errors excepted.

BERGOTHERM 700

Construction:

Conductor: pure nickel

Core insulation: special glass silk

Core identification: optional

Sheath insulation: special glass silk

Nominal voltage:     300/500 V 0.6 / 1 kV

(further voltage ranges on request)

Temperature range:  -50 ° C to + 700 ° C, briefly: + 1575 ° C

  • good resistance to thermal shocks
  • excellent aging in hot and cold environments
  • only suitable for fixed installation in a dry environment

Optional:

Shield braid (pure nickel)

Thermo or compensation line

Setup according to individual customer requirements

Changes and errors excepted.

BERGOTHERM 1200

Construction:

Head: Special Alloys

Core insulation: special ceramic braid

Core identification: optional

Sheath insulation: special ceramic braid

Nominal voltage:     300/500 V 0.6 / 1 kV

(further voltage ranges on request)

Temperature range: -50 ° C to + 1200 ° C, briefly: 1800 ° C

  • good resistance to thermal shocks
  • excellent aging in hot and cold environments
  • only suitable for fixed installation in a dry environment

Optional:

VA braid

Setup according to individual customer requirements

Changes and errors excepted.

 

Inquiry Form